Premises Information

Return to Inspections
NameSYCAMORE AT TYVOLA
Address707 SYCAMORE CENTRE DR
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/30/2026
Final Score @ Grade
16
General CommentsInspection conducted with CPO Michael. EHS will make return visit to re-verify facility's night swimming approval. NOTES: 1) SEE PDSC FORM FOR DOCUMENTATION OF IMPELLER/PUMP. 2) APPROVED FOR NIGHT SWIMMING 5/30/2023 - REVISIT 2026

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator. Observed chlorine measuring low, less than 1.0 ppm. CPO added more chlorine tablets into the erosion feeder to bring chlorine up. EHS confirmed chlorine was measuring at 1.5 ppm. No permit action.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed all skimmers completely full of debris. CPO dumped out skimmers during inspection.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed one missing endcap on one of the ladders. Replace missing endcap to prevent damaging pool wall.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed gate located near the fire pit area unable to self-close and self-latch. Bottom of the gate gets caught on the cement floor. CPO adjusted balance on the fencing and EHS confirmed gate was now able to self-close and self-latch. No permit action.