Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMAA UPTOWN
Address515 W 7TH ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/16/2025
Final Score @ Grade
22
General CommentsCOULD NOT VERIFY GROUND LEVEL WINDOWS DO NOT OPEN MORE THAN 4 INCHES DUE TO ACCESS. MAINTENANCE TECH. STATED WINDOWS DO NOT OPEN MORE THAN 4 INCHES AND THEY HAVE A BLOCKER. APPROVED POOL RESTROOM IS IN POOOL LOUNGE - FURTHEST ENTRANCE. FRONT RESTROOM DOES NOT HAVE FLOORS SLOPED TO DRAIN. NEW PUMP INSTALLED 2021 - BARELY MEETS TURNOVER. IF CLARITY BECOMES AN ISSUE PUMP WILL REQUIRE CHANGE TO PUMP - WATER CLARITY WAS FINE TODAY. NIGHT SWIMMING NOT PERMITTED.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. PH recorded at 7.0 CDI - Soda ash added to increase level to 7.2
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Skimmer baskets dirty with debris. CDI - Cleaned.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Incorrect phone number posted on sign. CDI - Correct phone number posted during inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(6) Provide sufficient lighting in chemical storage room. No Iighting in back chemical room. Provide lighting.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. No labels on pipes. Provide labels on pipes.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No .2526(a) Post a shower sign visible upon entrance to the pool. No shower sign visible. CDI - Shower sign provided during inspection.