Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMAA UPTOWN
Address515 W 7TH ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/31/2023
Final Score @ Grade
26
General CommentsOnsite visit to pool with Patrick Sills for construction final on pool restroom renovations. Flooring not sloped to drain. Floor specs reviewed and show slip-resistant for flooring in restrooms and in lounge area. Given 30 days to correct flooring or permit will be suspended. Repair of flooring must be completed so that at least one restroom is available at all times to the public while pool is operational. Hold will not be released on project until flooring is repaired. Lounge does not have door that self-closes, self-latches. Off at time of inspection. Area inside lounge is approved as "pool deck" with removal of the refrigerator. If seeking to use refrigerator, door must be made to self-close, self-latch with battery back-up on magnet latch. Mirrors installed in restrooms are shatterproof per provided specification. 15 - Ring buoy grab rope starting to degrade. Replace with new USCG approved ring buoy within 1 week. Will verify on return visit for gates. Permit conditionally issued. No night swimming. Sticker provided while onsite. A return visit will be made in 1 week to verify gates and ring buoy. A return visit will be made in 30 days to verify completion of the restroom repair. Note: Pump barely meets turnover. If clarity becomes an issue, pump may be required to be changed.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Section for main drain checks not present on log book. Provide section for DAILY main drain checks. Provided log book during site visit to operator.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Opening between light and wall on both lights. Openings <1/2". Continue to monitor. If >1/2", then requires repair. Some tiling missing off of pool walls. Monitor. Keep in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Both gates with 44" between horizontals. Operator stated plexiglass had been present previously but was removed approx. 5 years ago. Maintain 45" between horizontals. Given 1 week to correct gates or permit will be suspended. Eliminate horizontals from outside of barrier on gates. Window limiters could not be verified on windows due to access. Ensure windows limited at 4" from all windows opening on to pool deck. Barrier with <45" between horizontals. Pool built pre-2010. Benches located outside of barrier within 45" of barrier provide footholds. Pool built pre-2010. Eliminate footholds.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some cracking on pool deck. Offsets not >1/2". Monitor and repair if worsens.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light not functional in chemical storage room. Provide lighting. Bags of bicarb stored on chemical storage room floor. Maintain chemical storage up off the floor.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No No labeling on pipes in pump room. Clearly identify all piping by color codes or labels.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No No shower sign posted. Temporary signage posted during the inspection.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap/paper towels in restrooms. Provide soap and paper towels.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Hose bibs in new pool lounge/restrooms without backflow prevention devices. Provided backflow prevention device during inspection. Fill line without check valve. Original construction. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.