Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be lower than 6.8, off of the inspection scale. -CDI pH was adjusted during the inspection. Corrected to 7.4. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Observed 2 suction lines left open and on. This was a hazard. Lines were shut off and capped. Keep the lines capped when not in active use. Do not leave the lines on when not actively in use. -CDI. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Observed pool wall depth markers at far end of pool to be greater than 25ft. apart. Provide proper depth makers for pool wall. This was noted on the previous inspection and was not corrected.
DEPTH MARKERS MUST BE NO MORE THAN 25FT. APART MEASURED AROUND THE EDGE OF THE WATER. ALL DEPTH MARKERS MUST BE 25FT. OR LESS APART (DECK AND WALL). DEPTH MARKERS MUST HAVE NUMBERS AND FRACTIONS THAT ARE AT LEAST 4 INCHES IN HEIGHT, AND BE EXPRESSED IN FEET OR IN FEET AND INCHES. -CDI Depth markers were obtained and placed in proper locations. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed ladder missing rubber foot. Replace the rubber ladder foot. This was noted on the previous inspection and was not corrected. Correct this item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Fence not built to current specifications. Built prior to 2010. Observed gates to have footholds. Footholds were covered -CDI Observed doors into pool area not self-closing and self-latching and to have had the audible alarm disabled. Do not disable the alarm unless the door self-closes and self latches. Alarm was enabled. -CDI This was noted on the previous inspection. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed deck items to be too close to the pool edge. Items were pushed back. -CDI Keep items pushed back 6 feet or more from the pool edge. If this cannot be maintained properly, items will have to be removed from the pool deck. This was noted on the previous inspection. |