Inspection Date 6/10/2021
Final Score @ Grade
26
General CommentspH, chlorine, and main drains must be checked once a day when the pool is open. Total Alkalinity and Cyanuric Acid (if in use) must be checked once a week, 100ppm maximum. Keep log book properly. CONTINUE TO FOLLOW ALL RELEVANT COVID RULES POOL HAS PASSED INSPECTION AND BEEN ISSUED THEIR PERMIT STICKER. PAPER PERMIT WILL BE AVAILABLE ON-LINE FOR DOWNLOAD AND PRINTING AT OUR POOLS WEBSITE. POST PERMIT AND STICKER WERE VISIBLE AT POOL AREA. CPO AGREED TO EMAIL COPY OF REPORT NO SIGNATURE DUE TO COVID-19 PRECAUTIONS.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be lower than 6.8, off of the inspection scale. -CDI pH was adjusted during the inspection. Corrected to 7.4.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Observed 2 suction lines left open and on. This was a hazard. Lines were shut off and capped. Keep the lines capped when not in active use. Do not leave the lines on when not actively in use. -CDI.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Observed pool wall depth markers at far end of pool to be greater than 25ft. apart. Provide proper depth makers for pool wall. This was noted on the previous inspection and was not corrected. DEPTH MARKERS MUST BE NO MORE THAN 25FT. APART MEASURED AROUND THE EDGE OF THE WATER. ALL DEPTH MARKERS MUST BE 25FT. OR LESS APART (DECK AND WALL). DEPTH MARKERS MUST HAVE NUMBERS AND FRACTIONS THAT ARE AT LEAST 4 INCHES IN HEIGHT, AND BE EXPRESSED IN FEET OR IN FEET AND INCHES. -CDI Depth markers were obtained and placed in proper locations.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed ladder missing rubber foot. Replace the rubber ladder foot. This was noted on the previous inspection and was not corrected. Correct this item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fence not built to current specifications. Built prior to 2010. Observed gates to have footholds. Footholds were covered -CDI Observed doors into pool area not self-closing and self-latching and to have had the audible alarm disabled. Do not disable the alarm unless the door self-closes and self latches. Alarm was enabled. -CDI This was noted on the previous inspection.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed deck items to be too close to the pool edge. Items were pushed back. -CDI Keep items pushed back 6 feet or more from the pool edge. If this cannot be maintained properly, items will have to be removed from the pool deck. This was noted on the previous inspection.