| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Observed chlorine to pe 0.0ppm. Chlorine must be 1.0ppm minimum for safety. I.S Issued. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed no log book entry for September. Observed log entries missed during weekends. pH, chlorine, and main drains must be checked once a day when the pool is open. Total Alkalinity and Cyanuric Acid (if in use) must be checked once a week, 100ppm maximum. Keep log book properly. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Observed walls spotted with biofilm. Keep pool clean. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Observed pool wall depth markers at far end of pool to be greater than 25ft. apart. Provide proper depth makers for pool wall.
DEPTH MARKERS MUST BE NO MORE THAN 25FT. APART MEASURED AROUND THE EDGE OF THE WATER. ALL DEPTH MARKERS MUST BE 25FT. OR LESS APART (DECK AND WALL). DEPTH MARKERS MUST HAVE NUMBERS AND FRACTIONS THAT ARE AT LEAST 4 INCHES IN HEIGHT, AND BE EXPRESSED IN FEET OR IN FEET AND INCHES. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed ladder missing rubber foot. Replace the rubber ladder foot. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Observed pool floor return fittings missing or shifted. provide proper covers in proper position at all water returns. Observed gaps around the back end of the 6HP skimmer EQ line covers. Either move the covers closer into the wall, or fill the gap with underwater caulk or other such material. Fix the gap at all EQ covers which have such a gap. Observed vacuum line to not have a cover. provide a cover or plug. Cover or plug may not stick out more than 2 inches into the pool. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed ring buoy damaged. Observed no rope on ring buoy. Ring buoy was replaced and rope found and attached. Rope was made 44ft. long as is required for this pool. -CDI. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Fence no built to current specifications. Built prior to 2010. Observed gate latch damaged and non-functional. Observed gates to have footholds. Observed doors into pool area not self-closing and self-latching. Correct the gates so that they have proper latches.
Correct the footholds. DOORS MUST FULLY SELF-CLOSE AND SELF-LATCH OR BE FULLY SELF-CLOSING AND FITTED WITH AN AUDIBLE ALARM. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed deck items to be too close to the pool edge. Items were pushed back. -CDI Keep items pushed back 6 feet or more from the pool edge. If this cannot be maintained properly, items will have to be removed from the pool deck. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Observed kings III box non-functional. Box must function and have a working call-back number that is posted with local 911 service along with the proper address. Proper address and call-back number must correct and on file with local 911. . Call back number and address must be both properly posted on the sign and on file with local 911. Call back number must ring back the call box for voice communication with the box. |