Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSAVOY APARTMENTS
Address650 E BROOKLYN VILLAGE AV
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/21/2025
Final Score @ Grade
42
General CommentsImmediate Suspension issued for: .2535 - maintain chlorine at least 1.0 ppm .2535 - maintain pH at 7.2 to 7.8 .2530 - replace ring buoy rope with 33 ft. rope .2518 - repair multiport so pump can be turned on for turnover and circulation Ensure CPO is visiting property daily to reopen. Once corrected, contact Katie to reopen the pool. The pool shall remain closed until a return visit has been made. 704-309-5494. Pool closed signs posted during the site visit.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Chlorine at 0.6 ppm. Maintain chlorine through chlorinator at least 1.0 ppm. Immediate Suspension issued.
3 6 Water quality: pool water pH No No No Pool pH at 7.0. Maintain pool pH at 7.2 to 7.8. Immediate Suspension issued.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No main drain checks for month of July. Maintain daily record keeping for main drain checks. CPO on vacation week of 7/21. For pool to be reopened, pool CPO must be present for daily visits.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some algae on pool walls and around ladders. Keep walls clean.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Water level low. Multi-port damaged and backwash could not be turned off. Bring water level up so skimmers operate per NSF standard. Required to reopen the pool.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Some build-up on waterline tile and depth markers. Keep clearly visible. Still visible at time of inspection.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy rope degrading. Replace ring buoy with 33 ft. rope. Immediate Suspension issued.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Automated feeder could not be verified. Pump not operable due to damaged multiport. Pump was turned off. Feeder shall detect flow with loss of power from the pump.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Could not verify flow meter, pressure gauge, or equipment operable. Pump turned off at time of inspection due to damaged multiport. Repair multiport. Pump shall be operable to reopen the pool. Immediate Suspension issued for pump inoperable.