Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSHERATON HOTEL CHARLOTTE
Address555 S MCDOWELL ST
 
City/State/ZIP
CHARLOTTE NC 28204
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/19/2023
Final Score @ Grade
10
General CommentsI.T.S. Issued. Deadline is 10/19/2023. Failure to correct items by the deadline will result in the closure of the pool until the violations are resolved. The 2 Waterway 640-8240X EQ line covers in the pool will expire in June 2024. They will need to be replaced with an appropriate cover prior to the expiration date and the PDSC paper work will have to be turned into the Health Department for approval prior to that date.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. Observed only partial records kept since a least May 2023. Observed no records kept for September 2023. Proper records must be kept. I.T.S. Issued.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed step railing to be broken and loose. Repair this railing.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed deck doors not fully self-closing and fully self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. I.T.S. Issued.