| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 7.0 at time of inspection.
.2535(1) Maintain pH at 7.2 to 7.8.
Operator corrected to 7.4. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records missing since 7/31 on day of inspection, 8/12.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
*Permit item |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Tiling of pool wall missing at stair entry. Keep in good repair.
*Permit item |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Debris in skimmers. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected. |
|
10
|
2
|
Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints |
No |
No
|
No |
Safety rope at breakpoint missing colored floats together at one end, not 5 ft apart at time of inspection.
.2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less.
Operator adjusted floats and corrected. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Buoy rope tangled on chair, not attached to buoy, floating in pool, at time of inspection. Keep accessible.
.2530(a) Lifesaving equipment should be conveniently located and maintained in good repair for use in case of emergency.
Operator attached rope and placed in accessible location. Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fencing < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Door from clubhouse not latching or alarmed.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
Operator corrected to self-close, self-latch. Corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Deck and coping chipped greater than 1/2” at 3 FT and 4 FT by stairs and corner of deck by grill at 6 FT. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
*permit item
Chairs within 6’ of pool.
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Lighting fixture not securely attached to wall at time of inspection. .2524(c) Lighting fixtures shall not present a hazard to the public.
*Permit item |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Missing inlet fitting at 6 FT by grill area. 2518(i) Arrange inlets to produce uniform circulation.
*Permit item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals and other items stored near pool equipment in equipment room. Pool built 1985. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No airgap on backwash line. Pool built in 1985. .2513(b) Filter backwash shall be discharged through an air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No soap in men’s restroom.
.2526(j) Provide soap and soap dispenser, no glass, at each sink. |