Inspection Date 6/16/2025
Final Score @ Grade
16
General CommentsVisit to lift suspension and conduct permit inspection. Suspension was issued for high cyanuric acid, over 100 ppm and inlet fittings missing, expired ITS items. At time of visit, inlet fittings replaced. Cyanuric acid still over 100 ppm. Operator backwashed and added water to lower by end of day at return visit, 80 ppm. Issued permit. Salt not approved as primary. Coping starting to chip by corner at 6 FT end/grill area and right before breakpoint at 4 FT depth marker. Repair before this worsens to avoid permit action in the future. Pool not heated. No night swimming. Inspection with Aziz Hughes and Travis Horton

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Weekly cyanuric acid and alkalinity checks missing. Records not up to date, but pool closed at time of visit. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and corrected. Cyanuric acid over 100 ppm at time of inspection (expired Intent to Suspend item, resulting in suspension of permit) .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. Left property and returned. Operator backwashed pool and lowered to 80 ppm by end of day.
10 2 Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints No No No Safety rope at breakpoint missing colored floats, more than 5 ft apart at time of inspection. .2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less. Operator left property and replaced missing floats. Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fencing < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Door from clubhouse not latching or alarmed. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator corrected to self-close, self-latch. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals and other items stored near pool equipment. Pool built 1985. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
27 2 Equipment room: filter backwash discharged through an air gap No No No No airgap on backwash line. Pool built in 1985. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No paper towels in restrooms. Provide hand drying.