Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCROSSING AT QUAIL HOLLOW, THE
Address8850 PARK ROAD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/15/2024
Final Score @ Grade
32
General CommentsPermit items: Records, doors and windows onto pool deck, coping/deck repaired, skimmer baskets replaced where damaged and ladder. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS “W” Intent to Suspend (ITS)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Chlorine 0.5 ppm. .2535(4) Maintain chlorine at least 1.0 ppm. Operator turned up chlorinator and corrected to 1.0 ppm.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Weekly cyanuric acid and alkalinity checks missing. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *Permit item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets broken. .2518(k) Replace missing or damaged skimmer basket. *permit item
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder missing bottom step. 2521 Install ladders per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fencing < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Window from gym capable of opening > 4”. .2528(a) Ground level windows shall not open greater than 4" on to pool deck. *Permit item Door from clubhouse not latching or alarmed. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. *Permit item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck and coping chipped greater than 1/2” at 3 FT and 5 FT. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. *permit item Note: If work/deck is replastered, ensure paperwork is submitted to Health Dept for approval.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Inlet fitting missing. .2518(i) Provide inlet fittings in good repair. Operator replaced and corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet. .2533(d) Pump room floor shall be kept dry and free of standing water. Chemicals on floor and other items stored near pool equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
27 2 Equipment room: filter backwash discharged through an air gap No No No No airgap on backwash line. Pool built in 1985. .2513(b) Filter backwash shall be discharged through an air gap.