NameCROSSING AT QUAIL HOLLOW, THE
Address8850 PARK ROAD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/23/2024
Final Score @ Grade
14
General CommentsInspection conducted with CPO Jonathan Montalvo. Coping chipping in places. Maintain in good condition. Intent to suspend issued 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose. .2521 Install ladders per manufacturer instructions. Handrail missing escutcheon plate. .2521 Install handrails per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fencing < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Magna Latch < 54” high. .2528(a) Gate latches shall be 54" in height. - Corrected. Window from office kitchen capable of opening > 4”. .2528(a) Ground level windows shall not open greater than 4" on to pool deck. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed 2” flow meter installed on 3” return line. .2518(g) Install flow meter on return line per manufacturer instructions. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump roof floor wet. .2533(d) Pump room floor shall be kept dry and free of standing water. Chemicals and other items stored near pool equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No airgap on backwash line. Pool built in 1985. .2513(b) Filter backwash shall be discharged through an air gap.