Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCROSSING AT QUAIL HOLLOW, THE
Address8850 PARK ROAD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/25/2023
Final Score @ Grade
48
General CommentsImmediate suspension issued for water quality, buoy rope and emergency phone. Contact Marie Daley at 704-507-6806. When in compliance to lift suspension. Will verify other *permit items at this time. “E” Immediate suspension Lily Dominguez, manager present

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Chlorine 0.8 ppm. .2535(4) Maintain chlorine at least 1.0 ppm. *Immediate suspension item
3 6 Water quality: pool water pH No No No pH 6.8 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. **Immediate Suspension item. Contact Marie Daley 704-507-6806 when corrected to lift suspension.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Weekly cyanuric acid and alkalinity checks missing. Records not accurate and no maintenance or chemicals recorded for out of range water quality. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *Permit item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir missing. .2518(k) Replace missing weirs. *permit item
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Buoy rope tangled at time of inspection. Keep accessible. .2530(a) Lifesaving equipment should be conveniently located. *Immediate suspension item
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate missing magnalatch. Not self-closing, self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. *Permit item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck and coping chipped greater than 1/2” at skimmer basket. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. *permit item
22 6 Premises: emergency telephone provided No No No Emergency phone not operating at time of inspection. Kings III unable to transfer call to 911 and dispatcher stated someone would be sent out to address. .2530(f) Emergency phone shall remain operable. .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. *Immediate Suspension item. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Inlet fitting missing on 6 FT side, open hole in wall. .2518(i) Provide inlet fittings in good repair. *permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Items around pump and equipment. No backflow prevention on hose. Water on floor in pump room. Ventilation not working in pump/chemical room. Chemicals stored in pump room. Pool built '85. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump and chemical storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(d) Pump room floor shall be kept dry and free of standing water. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No airgap on backwash line. Pool built ‘85. .2513(b) Filter backwash shall be discharged through an air gap.