Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCROSSING AT QUAIL HOLLOW, THE
Address8850 PARK ROAD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/12/2022
Final Score @ Grade
22
General CommentsCPO updated to Jonathan Montalvo Inspection with Ozman Borjas

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Weekly cyanuric acid checks missing. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked, recorded and corrected.
10 2 Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints No No No Safety rope missing at breakpoint at time of inspection, floats more than 5 ft apart when replaced. .2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less. .2523(e) Provide a minimum of 3/4 inch diameter safety rope at the breakpoint. Operator replaced rope and adjusted floats. Corrected.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Buoy rope tangled at time of inspection. Keep accessible. Operator untangled rope for buoy and corrected. .2530(a) Lifesaving equipment should be conveniently located.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operating at time of inspection. .2518(g) Keep flow meter operational. Operator replaced with new and corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Items around pump and equipment. Water on floor. Ventilation not working in pump/chemical room. Chemicals stored in pump room. Pool built '85. .2533(c) Valves and controls shall be accessible to the pool operator at all times. No backflow prevention on hose bib. Maintain 3 ft. clear walking space in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump and chemical storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(d) Pump room floor shall be kept dry and free of standing water. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No airgap on backwash line. Pool built ‘85. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Soap dispenser in women’s restroom appears to be glass. .2526(j) Provide soap and soap dispenser, no glass, at each sink.