11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder loose and not secure at 6 FT end of pool. .2521 Install ladders per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Buoy rope tangled at time of inspection. Outer rope on buoy torn, not in good repair. Keep accessible. Operator untangled, tied to buoy and corrected.
.2530(a) Lifesaving equipment should be conveniently located. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Drain spout creating horizontal less than 45" in height.
.2528(b) Horizontals shall not be located less than 45" in height.
Window onto pool deck opening greater than 4".
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm.
Magna-latch measured at 53" from ground. .2528(a) Gate latches shall be 54" in height.
*Permit items |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not operating at time of inspection.
.2530(f) Emergency phone shall remain operable.
*Immediate Suspension item. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not operating at time of inspection.
.2518(g) Keep flow meter operational.
*permit item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Items around pump and equipment. Ventilation not working in pump/chemical room. Chemicals stored in pump room. Pool built '85. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump and chemical storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No airgap on backwash line.
.2513(b) Filter backwash shall be discharged through an air gap. |