Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCROSSING AT QUAIL HOLLOW, THE
Address8850 PARK ROAD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/21/2022
Final Score @ Grade
26
General CommentsImmediate suspension issued for emergency phone. Posted 'pool closed' signs. Pool MUST REMAIN CLOSED with signage posted until suspension is lifted by Health Dept. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. "E" Immediate Suspension status Other permit items to verify include flow meter operational, 54" latch on gate, window not opening greater than 4" onto pool deck or alarmed and horizonal eliminated from drain spout. Salt not approved as primary chlorination. Inspection with Oznan Borjas No signature due to COVID

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose and not secure at 6 FT end of pool. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Buoy rope tangled at time of inspection. Outer rope on buoy torn, not in good repair. Keep accessible. Operator untangled, tied to buoy and corrected. .2530(a) Lifesaving equipment should be conveniently located.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Drain spout creating horizontal less than 45" in height. .2528(b) Horizontals shall not be located less than 45" in height. Window onto pool deck opening greater than 4". .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Magna-latch measured at 53" from ground. .2528(a) Gate latches shall be 54" in height. *Permit items
22 6 Premises: emergency telephone provided No No No Emergency phone not operating at time of inspection. .2530(f) Emergency phone shall remain operable. *Immediate Suspension item. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operating at time of inspection. .2518(g) Keep flow meter operational. *permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Items around pump and equipment. Ventilation not working in pump/chemical room. Chemicals stored in pump room. Pool built '85. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump and chemical storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
27 2 Equipment room: filter backwash discharged through an air gap No No No No airgap on backwash line. .2513(b) Filter backwash shall be discharged through an air gap.