Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCROSSING AT QUAIL HOLLOW, THE
Address8850 PARK ROAD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/10/2021
Final Score @ Grade
36
General CommentsImmediate Suspension issued for chlorine tablets in skimmers. Chlorinator must work and tablets removed from pool. Contact Marie Daley at 704-507-6806 when corrected to lift suspension. Pool MUST REMAIN CLOSED until suspension is lifted by health Dept. Changed to "E" Immediate Suspension **Skimmer equalizers are still NOT PLUGGED in skimmer from last inspection. Skimmers must be plugged in skimmer line per State Recommendations. Must be corrected prior to issuance of 2021 permit** Permit items: records, skimmer line plugged in wrong hole, trip hazards greater than 1/2" and loose coping, chlorinator and flow meter. No Night Swimming. May not use salt as primary chlorination. No signature due to COVID Inspection with Jose Rodriguez and Andrew Morris Report to Crossing at Quail Hollow Manager Crossing at Quail Hollow Service

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Chlorine tablets observed in skimmer baskets. G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. *Immediate Suspension item. Contact Marie Daley at 704-507-6806 when chlorinator is fixed and chlorine is being added through chlorinator, not directly to pool. Pool MUST REMAIN CLOSED with "Pool Closed" signs posted until suspension is lifted by Health Dept.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records are not being kept daily (observed a few days recorded/week). No weekly cyanuric acid or alkalinity recorded. .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *permit item
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Skimmer equalizer lines observed plugged on wall, but NOT in skimmer. One skimmer basket plugged in wrong line. These need to be plugged per State Recommendations (in skimmer and on wall) prior to issuance of 2021 permit. Permit will be DENIED if this is not corrected.** .2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. *permit item
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose and not secure at 6 FT end of pool. .2521 Install ladders per manufacturer instructions.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck and coping chipped greater than 1/2" in multiple places and at skimmer basket and loose, cracked coping around pool. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. .2537(3) There shall be no loose coping. *permit item
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Chlorinator not working at time of inspection. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions.*permit item
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operating at time of inspection. .2518(g) Keep flow meter operational. *permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Items around pump and equipment. Leak at filter and water on floor of pump room. Ventilation not working in pump/chemical room. Chemicals stored in pump room. Pool built '85. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. .2533(e) Provide continuous forced ventilation or cross ventilation in pump and chemical storage room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. Pool built '85. .2513(b) Filter backwash shall be discharged through an air gap.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No Unable to locate hose bib for restroom at time of inspection. Pool built '85. .2526(d) Provide hose bib so that all parts of restroom can be reached with a 50 ft hose.