1
|
6
|
Water quality: water clear enough to clearly see bottom of pool and pool drain |
No |
No
|
No |
Some leaves on main drain.
.2535(2) Main drains must be clearly visible from the pool deck.
**Immediate Suspension item. Contact Marie Daley 704-507-6806 when corrected to lift suspension. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 8.0 at time of inspection.
.2535(1) Maintain pH at 7.2 to 7.8.
**Immediate Suspension item. Contact Marie Daley 704-507-6806 when corrected to lift suspension. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Buoy rope tangled at time of inspection. Rope over 50'. Keep accessible. Operator untangled, cut to 45' and corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Cracked and loose coping by 4' and 5' areas of pool. Tile missing on wall at shallow end. Cracks in deck causing more than 1/2" offsets. Fill spout has been removed and leaving PVC piece protruding out of pool deck. Remove and cover trip hazard greater than 1/2" or meet compliance for fill spout. .2512(c) Over the rim fill spout shall be located under the diving board or within six inches of a ladder or handrail. .2537(3) There shall be no loose coping. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Chairs within 6' of pool on shallow side. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved chairs and corrected. *ITS item |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Inlet fitting missing piece. Some inlets protruding from wall, potential entrapment hazard and not installed in good repair. .2518(i) Provide inlet fittings in good repair.
*ITS item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Light out in equipment/chemical room at time of inspection. Chemicals stored in pump room. Liquid chemicals stored over dry chemicals. Items stored around piping. Pool built prior to 2004.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(6) Provide sufficient lighting in chemical storage room.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
No backflow preventer on hose bib. Provide anti-siphon or backflow prevention device. |