15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Buoy rope tangled at time of inspection. Rope over 50'. Keep accessible. Manager untangled, cut to 45' and corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Vacuum port observed with no cover at time of inspection. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Operator is ordering this item. Lack of severity does not warrant permit at this time. Will verify on next inspection. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Items stored around piping. Pool built prior to 2004.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
No backflow preventer on hose bib. Provide anti-siphon. |