Water quality: disinfectant residual provided by |
No |
No
|
No |
.2535(4) Maintain chlorine at least 1.0 ppm. Cl at 0.6 ppm.
G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. Chlorine pucks present in both skimmers.
*Immediate suspension items |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(d) All drain covers shall be kept in good condition. Missing, broken, or cracked fittings shall be replaced or reattached before the pool should be used. One of two equalizer covers missing - have been removed from equalizer line - open line present.
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. PDSC form shows 2 Waterway 640- equalizer covers. Covers have been changed and are now Aquastar covers. Submit PDSC showing change.
Permit restriction present pump should be locked at 2875 rpm to prevent flow rate from exceeding 63 gpm. Currently pump operating at 3450 rpm and 80 gpm verified at 75gpm on flow meter after backwash.
*Immediate suspension items |
|
10
|
2
|
Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints |
No |
No
|
No |
.2523(e) Provide a minimum of 3/4 inch diameter safety rope at the breakpoint. Observed no breakpoint safety rope installed. Has been removed due to damage. Replace. *permit item |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521 Install ladders per manufacturer instructions. Handrail at steps very loose - repair |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2537(b) All gates and doors shall be self-closing, self-latching. Observed gate near restrooms connected to office not self-closing or latching shut. *permit item |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
.2537(9) Underwater light niches shall be maintained or covered so not to present a hazard. Underwater light fixture detached from wall with electrical connections accessible to swimmers. *permit item |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Kings III box operator unable to transfer call to 911. Kings III box newly changed to cellular and programming not allowing operator to transfer.
*Immediate suspension item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(d) Pump room floor shall be kept dry and free of standing water. Whenever backwash activated, heavy overflow into pump room resulting in electrical equipment in standing water. Backwash pipework not sufficient for volume of water flow from system. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. Backwash pipe elbowed into backwash well such that no air gap is present. Pool built in 1981. |