Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBRIDGES AT QUAIL HOLLOW
Address7561 QUAIL MEADOW LN
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/25/2023
Final Score @ Grade
34
General CommentsInspection conducted with Christopher Luna and Leo Perozo. Immediate suspension of permit issued for the following items: Chlorine less than 1.0 ppm Chlorine pucks present in skimmer baskets Emergency phone system unable to route calls to 911 Suction outlet compliance - flow of system higher than permitted, equalizer cover missing, and change out of suction outlet covers without submittal of PDSC Additional items that may result in issuance of 30 day intent to suspend the permit: Gate not self closing/latching Missing floating safety rope Pool wall lighting detached PDSC forms can be found on the website health.mecknc.gov/envhealth/pools. Submit new pdsc showing equalizer cover change to pdsc@mecknc.gov. Permit will remain suspended until all immediate suspension items corrected and pdsc has been approved by the department. Call Hope McIntosh at 980-229-7549 once all items have been corrected. At that time, if any additional permit items remain out of compliance a 30 day intent to suspend may be issued.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Cl at 0.6 ppm. G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. Chlorine pucks present in both skimmers. *Immediate suspension items
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(d) All drain covers shall be kept in good condition. Missing, broken, or cracked fittings shall be replaced or reattached before the pool should be used. One of two equalizer covers missing - have been removed from equalizer line - open line present. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. PDSC form shows 2 Waterway 640- equalizer covers. Covers have been changed and are now Aquastar covers. Submit PDSC showing change. Permit restriction present pump should be locked at 2875 rpm to prevent flow rate from exceeding 63 gpm. Currently pump operating at 3450 rpm and 80 gpm verified at 75gpm on flow meter after backwash. *Immediate suspension items
10 2 Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints No No No .2523(e) Provide a minimum of 3/4 inch diameter safety rope at the breakpoint. Observed no breakpoint safety rope installed. Has been removed due to damage. Replace. *permit item
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Handrail at steps very loose - repair
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed gate near restrooms connected to office not self-closing or latching shut. *permit item
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No .2537(9) Underwater light niches shall be maintained or covered so not to present a hazard. Underwater light fixture detached from wall with electrical connections accessible to swimmers. *permit item
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Kings III box operator unable to transfer call to 911. Kings III box newly changed to cellular and programming not allowing operator to transfer. *Immediate suspension item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Whenever backwash activated, heavy overflow into pump room resulting in electrical equipment in standing water. Backwash pipework not sufficient for volume of water flow from system.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Backwash pipe elbowed into backwash well such that no air gap is present. Pool built in 1981.