NameBRIDGES AT QUAIL HOLLOW
Address7561 QUAIL MEADOW LN
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/24/2019
Final Score @ Grade
10
General CommentsDecking around handrails (ladder and stair entry) and where chipping (corner near entry gate) must be repaired prior to 2020 permit (offsets starting to crack, currently less than 1/2" offset) Chris King, pool management company installed new covers in May 2019, vebal verified flow rating of 191 gpm and 2" pipe for equalizer covers (Waterway 640-8200, not 82XX). Flow rating does not warrant immediate suspension due to approval without suction hazard, but must update PDSC form on file to avoid permit action.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gates not self-latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. Operator corrected to self-close, self-latch.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some chemicals stored on ground (salt)/bag of sodium bicarb, chlorine stored in pump room. No ventilation in chemical room. No clear walking space around piping. Pool built prior to 2004. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Labeling on piping starting to fade. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap.