NameBRIDGES AT QUAIL HOLLOW
Address7561 QUAIL MEADOW LN
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/23/2019
Final Score @ Grade
18
General CommentsPermit issued with No Night Swimming. Decking around handrail and where chipping must be repaired prior to 2020 permit (offsets starting to crack, currently less than 1/2" offset) Approved PDSC form.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Grate missing from pool wall, creating gap/offset/hazard. Keep in good repair. Operator replaced. Corrected.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed one of two weirs missing at time of inspection. .2518(k) Replace missing weirs. Operator replaced. Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Windows from clubhouse onto pool deck with stoppers not operating. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Operator adjusted stoppers to work. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some chemicals stored on ground (salt), chlorine stored in pump room. No ventilation in chemical room. No clear walking space around piping. Pool built prior to 2004. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Labeling on piping starting to fade. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. .2513(b) Filter backwash shall be discharged through an air gap.