21
|
0
|
Proper hot holding temperatures |
Yes |
No
|
No |
3-501.16(A)(1) Maintain TCS foods in hot holding at 135F or above. -P. Observed chicken hot holding in hot box below 135F. PIC stated item was in the hot box less than 2 hours. CDI: Chicken was reheated to above 165F. All other hot holding was in compliance.
For more information, please visit: http://meck.co/FoodSafety or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Safe Food Temperatures https://youtu.be/tXP09IK-1TQ . |
|
22
|
1.50
|
Proper cold holding temperatures |
Yes |
No
|
No |
3-501.16(A)(2) Maintain TCS foods in cold holding at 41F or less. -P. Observed multiple items in prep unit (top and bottom) above 41F. See temperature chart. PIC stated all items were in the unit for less than 4 hours. Maintenance person expected today or tomorrow. CDI: Items were moved to walk in cooler to quickly cool.
Compliance visit will be made.
For more information, please visit: http://meck.co/FoodSafety or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Safe Food Temperatures https://youtu.be/tXP09IK-1TQ |
|
33
|
0.50
|
Proper cooling methods used; adequate equipment for temperature control |
Yes |
No
|
No |
3-501.15 Quickly cool foods. Use methods such as open/vented shallow pans, large ice baths and active stirring. Cold air must flow around product to remove the heat. -Pf For more information please visit: http://meck.co/FoodSafety or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Cooling Food Safely https://youtu.be/P6x8b1ZVOxU . Observed sausage gravy cooling in a large pan at a rate of 0.06F/min. CDI: PIC placed item in walk in freezer to quickly cool. |
|
41
|
0
|
Wiping cloths: properly used & stored |
Yes |
No
|
No |
3-304.14(B) Hold in-use wiping cloths in properly concentrated sanitizer between uses. Observed in use wiping cloths being held in 10ppm chlorine. CDI: bucket was changed new concentration is 50ppm. |
|
55
|
0.50
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
REPEAT