2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Chlorine 0.4 ppm at time of inspection.
.2535(4) Maintain chlorine at least 1.0 ppm.
**Immediate suspension item. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 7.0 at time of inspection.
.2535(1) Maintain pH at 7.2 to 7.8.
**Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records available for pool for last few days prior to inspection. No maintenance recorded. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
*permit item |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
2 weirs observed missing at time of inspection.
.2518(k) Replace missing weirs. Operator replaced and corrected.
Debris and leaves in all skimmers. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied skimmer baskets and corrected. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Entry handrail at sunshelf loose and not secure. Keep tight and in good repair. .2521 Install ladders and handrails per manufacturer instructions. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs within 6' of pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Some chemicals stored in pump room. Items within 3' of clearance for equipment.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Some items within 3' of piping in pump room.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower off at time of inspection. .2526(h) Shower(s) shall be provided. |