Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameDAVIDSON EAST
Address16809 SETTER POINT LN
 
City/State/ZIP
DAVIDSON NC 28036
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/16/2026
Final Score @ Grade
16
General CommentsNo night swimming No glass in downstairs kitchenette Salt not approved as primary chlorination Digital flow meter must remain operable at max 274gpm for turnover.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed 4 missing weirs. CDI- Replaced
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Observed ground level window opening over 4”. CDI- Window bolted to open no greater than 4”.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed digital flow meter not operable. Flow meter was reading at 0ppm while pump was running. CDI- New flow meter installed.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No .2526(h) Shower(s) shall be provided. Observed shower with no running water.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(m) Keep restrooms and fixtures clean and in good repair. Observed no light in men’s restroom .2526(k) Provide shatterproof mirrors. Observed mirrors not shatterproof in restrooms