2
|
1
|
Certified Food Protection Manager |
No |
Yes
|
No |
2-102.12 (A) PIC shall demonstrate knowledge by being a certified food protection manager. Observed no CFPM on site.
For more information on becoming a certified food protection manager please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation |
|
3
|
1
|
Management, food & conditional employee; knowledge, responsibilities & reporting |
Yes |
No
|
No |
2-103.11(O) Ensure food employees are informed of their responsibility to report required symptoms, illnesses and exposure.-PF Observed no employee health policy. CDI- EHS left copy and reviewed policy.
For more information on employee health policy, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation |
|
5
|
0
|
Procedures for responding to vomiting & diarrheal events |
Yes |
No
|
No |
2-501.11 A food establishment shall have written procedures for employees to follow when responding to vomiting or diarrheal events. -Pf Observed no vomit/ diarrhea plan. CDI- EHS left copy of plan
For more information please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation |
|
38
|
0
|
Insects & rodents not present; no unauthorized animals |
No |
No
|
No |
6-501.111 Keep the premises free of insects, rodents, and other pests. Observed flies in kitchen area. |
|
47
|
0.50
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 Maintain equipment in good repair. Observed shelves rusted in walk in cooler.
4-205.10 Ensure equipment other than toasters, mixers, microwaves, water heaters and hoods is ANSI certified or equivalent. Observed facility with at home grill in use. PIC stated that he rolls in in the back and cooks food. Discontinue use of grill. |
|
55
|
0.50
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed concrete exposed throughout kitchen area. |
|
56
|
0
|
Meets ventilation & lighting requirements; designated areas used |
No |
No
|
No |
6-303.11 Provide required lighting intensity. Observed 3 ft candles in walk in cooler. Get more light. |