12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One eyeball fitting missing in deep end by main drains. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Sections of grout missing between travertine tiles and along coping. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter reading 120 GPM. .2518(b) The filtration system shall circulate and filter the entire volume of pool water four times or more in 24 hours. - Corrected to 132 GPM. |