Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBELMONT AT TRYON, THE
Address223 GLEN MYRTLE AVE
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/21/2025
Final Score @ Grade
12
General CommentsInspection conducted with CPO Jake Clifford and CPO Trevor Forde. Observed issues from this morning’s inspection have been corrected. Verified In-Field Plan Review - COM-ELC-25-001331 passed 5/9/2025 for new filtration and feature pumps Filtration - TR-140C filter 8 returns - 2.5” line 2 MD - 3” line 5 Skimmers 3” line Feature 6 returns - 2.5” line, also a 2” bypass line 2 MD - 3” line New permit condition that flow meter must remain operable and required at 132 to 138 GPM to meet turnover and flow restriction of suction line. Operator able to adjust flow to 132 GPM at 2455 RPM. Permit sticker issued with the following conditions: 1) Filtration Pump - Flow meter required operable. Flow required at 132 to 138 to meet turnover and flow restriction of the suction line. 2) Salt is not approved for primary chlorination. 3) 8 ft. clearance required around pool. 4) No night swimming Paper permit will be on our website, https://eh.mecknc.gov/pools, in 3-5 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One eyeball fitting missing in deep end by main drains. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Sections of grout missing between travertine tiles and along coping. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter reading 120 GPM. .2518(b) The filtration system shall circulate and filter the entire volume of pool water four times or more in 24 hours. - Corrected to 132 GPM.