2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Chlorine 0.8 ppm at time of inspection.
.2535(4) Maintain chlorine at least 1.0 ppm. Operator increases and corrected. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Main drains not checked daily and some readings missing.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
Operator added and corrected. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Depth marker covered by chair on perimeter wall. One depth marker not visible in mulch behind life saving equipment.
.2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. Moved chairs blocking markers and moved other depth markers to wall area. Corrected. Advised more permanent solution for the depth markers that are not in good repair. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
No flow meter on chlorinator. Install per NSF requirement. Original construction. If ever replaced, install as required. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No soap in men’s restrooms.