Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameFRANCIS, THE
Address400 E BROOKLYN VILLAGE AV
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/27/2023
Final Score @ Grade
16
General CommentsIntent to Suspend issued: .2535 - provide cyanuric acid reagent .2528 - repair gates and door to self-close, self-latch Naquan Brown during inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Some reagents expired. Multiple test kits. Only one cyanuric acid reagent and expired. Replace expired cyanuric reagent. Intent to Suspend issued. No logs in June. Records for July show same readings for chlorine, pH, CYA and TA. Ensure daily record keeping for chlorine and pH and weekly record keeping for cyanuric acid and total alkalinity.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Crack across pool floor in deeper end of pool. Continue to monitor. May require repair in the future if worsens. Stabilizer added to pool but not dissolved. Brushed into pool during the inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Two of three gates not closing/latching. Repair to self-close, self-latch. Intent to suspend issued. One door not closing/latching. Repair to self-close, self-latch. Handles on pool below 45". Original construction.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on chlorinator. Install per NSF requirement. Original construction. If ever replaced, install as required.