Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameFRANCIS, THE
Address400 E BROOKLYN VILLAGE AV
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/17/2023
Final Score @ Grade
20
General CommentsIntent to Suspend issued for the following: .2523/.2537 - provide depth marker on perimeter walls back from handicap lift and secure ft to wall at landscape area .2528 - repair push bar at entry near shower .2535 - maintain daily record keeping for chlorine, pH and main drain checks. Maintain weekly record keeping for cyanuric acid and total alkalinity. Replace ring buoy with USCG approved ring buoy by May 1. Permit will not be issued until items are corrected. A return visit will be required for verification. Luis Rosado present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Log book being maintained electronically. Could not view logs. If utilizing electronic logs, daily and weekly record keeping must be available for viewing. Intent to Suspend issued. Ensure daily record keeping for chlorine, pH and main drain checks. Weekly record keeping for cyanuric acid and total alkalinity.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Crack across pool floor in deeper end of pool. Continue to monitor. May require repair in the future if worsens.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Depth marker damaged on pool wall back from handicap lift. FT coming off of pool wall at corner of planter. Replace/repair depth markers so clearly visible. Depth marker lettering shall be contrasting and at least 4" in height. Intent to Suspend issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Handles on gates <40". Original construction. If ever replaced, raise to at least 40" - 45" measured from ground to meet ADA and rule requirement for horizontal. One gate with push bar not secure. Secure push bar so self-latching, self-closing. Intent to Suspend issued.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on chlorinator. Install per NSF requirement. Original construction. If ever replaced, install as required.