5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records not maintained in log book for June/July. August in logs. Maintain weekly record keeping for total alkalinity. Pool is on liquid and is not using stabilizer. Maintain daily record keeping for chlorine, pH and main drain checks. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Feature pump operable at time of visit. Per last inspection, new pump installed. Could not verify electrical permit has passed. Pump turned off during inspection. Provide electrical permit number and also updated PDSC form or permit will be suspended. Updated pdsc form required by 9/2/2021. New pump is Pentair Whisperflo XF, XFE-12, 3 hp pump. Same flow rating as previous pump XFK-12 at 222 gpm. No in-field plan review application required. No suction hazard. Could not verify electrical. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
New glass tile around cement wall on pool deck. Depth marker removed from wall when tile added. Install 3 ft. depth marker on wall directly back from the deck depth marker. Intent to Suspend item. Provide specifications for tile used on cement wall. No glass permitted on pool deck. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
One door closest to glass wall not self-closing, self-latching. Repair to self-close, self-latch. Intent to Suspend items.
Gate self-closure loose on gate closest to shower. Repair/tighten closure. Gate still self-closes and latches.
Handles at 39" from ground. Original construction. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone buzzing when picked up. Could not audibly hear 911. 911 could not audibly hear EHS. Immediate Suspension issued. New phone to be installed. Ensure phone rings back phone number posted when dialed. |