Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameFRANCIS, THE
Address400 E BROOKLYN VILLAGE AV
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/30/2021
Final Score @ Grade
24
General Comments17 - Pavers around pool sealed with polymeric sand. Sand beginning to erode in some locations. Continue to monitor. Pavers are required sealed with polymeric sand for approval and to maintain an impervious surface. May require repair prior to 2022 operating season if worsens. Immediate Suspension issued for the emergency phone. Once corrected, please contact Katie at 704-309-5494 to re-open the pool. The pool must remain closed until a return visit has been made. Also, feature pump must remain OFF until electrical permit is finaled and new pdsc form is submitted.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records not maintained in log book for June/July. August in logs. Maintain weekly record keeping for total alkalinity. Pool is on liquid and is not using stabilizer. Maintain daily record keeping for chlorine, pH and main drain checks.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Feature pump operable at time of visit. Per last inspection, new pump installed. Could not verify electrical permit has passed. Pump turned off during inspection. Provide electrical permit number and also updated PDSC form or permit will be suspended. Updated pdsc form required by 9/2/2021. New pump is Pentair Whisperflo XF, XFE-12, 3 hp pump. Same flow rating as previous pump XFK-12 at 222 gpm. No in-field plan review application required. No suction hazard. Could not verify electrical.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No New glass tile around cement wall on pool deck. Depth marker removed from wall when tile added. Install 3 ft. depth marker on wall directly back from the deck depth marker. Intent to Suspend item. Provide specifications for tile used on cement wall. No glass permitted on pool deck.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One door closest to glass wall not self-closing, self-latching. Repair to self-close, self-latch. Intent to Suspend items. Gate self-closure loose on gate closest to shower. Repair/tighten closure. Gate still self-closes and latches. Handles at 39" from ground. Original construction.
22 6 Premises: emergency telephone provided No No No Emergency phone buzzing when picked up. Could not audibly hear 911. 911 could not audibly hear EHS. Immediate Suspension issued. New phone to be installed. Ensure phone rings back phone number posted when dialed.