2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Pool chlorine at 0 ppm. Maintain at least 1.0 ppm through chlorinator. Immediate Suspension issued. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Crack in pool floor near bench. Continue to monitor. Does not appear to be a cut hazard at time of inspection.
Note - plaster at zero entry different color than main pool. Ensure reflectance at least 50%. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Wall depth marker on perimeter wall at 4 ft. shrunk to <4" in height. Replace wall depth marker. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Doors from club room not self-closing, self-latching. Repair all doors to self-close, self-latch.
Note: Horizontal handle on gates ranges from 39" to 40". If ever repaired/replaced, repair to at least 40" in height from ground. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
One bubbler light out on sun shelf. Repair light. Pool is not approved for night swimming. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not operable on backwash line. Repair flow meter. Backwash max flow at 300 gpm. Required for permit restriction from original construction. |