NameARBORMERE HOA
Address15708 FORELEIGH RD
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/13/2026
Final Score @ Grade
34
General CommentsNo permit restrictions Note: Equalizer lines must remain plugged in skimmer and on wall. Must be in good repair. Filtration pump pulls through two sets of drains. No night swimming Inspection completed with CPO Luke Fiser

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed PH at 7.0. CDI: corrected to 7.3 during inspection.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmers and skimmer baskets with debris. CDI: cleaned during inspection .
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Observed ladder ends that were without rubber bumpers on 5ft end close to clubhouse side.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed both ropes > 50ft. CDI: corrected to 50ft during inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010). Observed some areas > 2” under fence (built 2018). CDI: corrected to < 2” by CPO adding pine straws underneath fence.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool lawn chairs that were closer than 6 ft walking space around the pool. CDI: lawn chairs moved back to provide 6ft walking space.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed flow meter stuck to bottom. CDI: repaired and now working properly.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed bags of chemicals stored on floor in chemical storage room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. Observed labels on pipes not visible at time of inspection.