2
|
1
|
Certified Food Protection Manager |
No |
Yes
|
No |
2-102.12 (A) PIC shall demonstrate knowledge by being a certified food protection manager. Facility is operating whiteout a certified food protection manager present.
For more information on becoming a certified food protection manager please visit: www.mecknc.gov/foodsafety |
|
15
|
0
|
Food separated & protected |
Yes |
No
|
No |
3-302.11(A)(1) Separate raw animal foods from ready-to-eat foods and washed/unwashed fruits and vegetables. -P Observed raw meat being stored cooked chicken wings. CDI- PIC moved raw meat to proper storage area.
For more information on food storage order please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation |
|
23
|
1.50
|
Proper date marking & disposition |
Yes |
No
|
No |
3-501.17 Date mark/label all TCS foods that are ready-to-eat once opened or prepared and held more than 24hrs. -Pf Observed container of tomatoes, and other TCS foods in make table held over night being held beyond 24 hours. CDI- PIC labeled items.
For more information, please visit: www.mecknc.gov/foodsafety or view our training videos at the following weblinks: What are TCS Foods https://www.youtube.com/watch?v=q0iLZb7v0UM and Date Marking Food Safely https://youtu.be/BOPsSNUajYs . |
|
28
|
1
|
Toxic substances properly identified stored & used |
Yes |
No
|
No |
7-202.12(A) Use poisonous or toxic materials according to manufacturer's label. Use pesticides approved for use in commercial food service only.-P Observed a can of raid fogger spray being stored with the remaining chemicals. This pesticide is not approved for commercial use. CDI- PIC discarded raid. |
|
36
|
0.50
|
Thermometers provided & accurate |
No |
No
|
No |
4-302.12 Provide an accessible thermometer for use. Provide a thin probe thermometer for accurate measure of thin foods.-Pf . Observed facility using a thick probed thermometer. VR in ten days will occur. |
|
49
|
0.50
|
Non-food contact surfaces clean |
No |
No
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed grease buildup from hood vents and missing catch pan, grease is dripping down wall onto the floor. |
|
51
|
0
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-202.13 An air gap between the water supply and flood level rim shall be at least twice the diameter of the water supply inlet and not less than 1 inch.-P Observed improper air gap underneath 3-sink in dish area. VR will occur in 3 days. |
|
55
|
1
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed missing ceiling tiles above dish pit area. Cracked floors throughout kitchen. |