Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOURTYARDS AT KINNAMON PARK
Address9510 FAWNTAIL LN
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 6/7/2018
Final Score @ Grade
28
General CommentsIntent to Suspends issued for the following: 2528 - Large gate not self-closing. Repair to self-close. Meshing around push bar too large. Maintain no greater than 1/2" within 18" of latch mechanism. Meshing is 1/2" x 3/4". Green utility cover provides foothold next to fence. Eliminate foothold. 44 1/2" between horizontals on right side of large fence from outside. Maintain 45" between horizontals. 2535 - record alkalinity and acid weekly 2518 - Flow meter must meet 1.5x design flow of pump at least 135 gpm. Small leak at pipe at multi-port. Repair leak. 2533/2534 - Storage of chemicals in pump room and storage on floor in pump room. Provide 3 ft clear walking space around all equipment and maintain chemical storage in chemical storage room. 2526 - provide documentation for shatterproof mirrors in restrooms PDSC form is on old form with no date for expiration. PDSC form references incorect drain cover. Field built sumps. Engineer letter references WAV12 and not WAV12WRxxx which are what is installed. No suction hazard present. Property given one week to provide updated sump certification letter and updated PDSC form. Max Depth - 4 ft Pool Width - 20 ft Rope Length - 30 ft Pentair Whisperflo WFE-6 with (2) WAV12WRxxx drain covers

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Pool pH at 8.2. Corrected to 7.2 during inspection.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Cyanuric acid and alkalinity not recorded weekly. Record weekly. Intent to Suspend issued. One day with chlorine at 0 ppm. Pool not closed. If pool chlorine is below 1 ppm, pool shall be closed. Corrective actions shall be written in the log book.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Large gate not self-closing. Repair to self-close. Meshing around push bar too large. Maintain no greater than 1/2" within 18" of latch mechanism. Meshing is 1/2" x 3/4". Both gates. Green utility cover provides foothold next to fence. Eliminate foothold. 44 1/2" between horizontals on right side of large fence from outside. Maintain 45" between horizontals. Intent to Suspends issued for all listed items above.
22 6 Premises: emergency telephone provided No No No Dialing instructions incorrect and address incorrect at emergency phone. Corrected during inspection.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter does not meet 1.5 x design flow. Required to read at least 135 gpm. Flow meter must show required flow. Blue white flow meter installed. Ensure installed per manufacturer instructions. Intent to suspend issued. Small leak at pipe at multi-port. Repair leak. Intent to Suspend issued.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Storage of chemicals in pump room and storage on floor in pump room. Provide 3 ft clear walking space around all equipment and maintain chemical storage in chemical storage room. Intent to Suspend issued.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No documentation for shatterproof mirrors. Provide documentation for shatterproof mirrors. Intent to Suspend issued. General Comment - No paper towels in the men's restroom. Provide paper towels.