3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 7.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8.
**Immediate suspension item. Contact Marie Daley at 704-507-6806 when corrected to lift suspension. Pool must remain closed until return visit from health department to lift suspension.
Pool Closed signs posted. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Rubber cap missing on left hand ladder. .2521 Install ladders per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Buoy rope tangled at time of inspection. Keep accessible. Operator untangled and corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some chairs within 6' of pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved chairs and corrected.
**Note: Tile by autofill loose. Maintain no greater than 1/2" offsets on pool deck. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck at time of inspection. .2518(g) Keep flow meter operational.
**ITS item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals (salt for pool) stored in extra room by pool. Chemical room open into pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Some water on floor in pump room. Not draining to floor drain..2533(d) Pump room floor shall be sloped to drain.
.2533(d) Pump room floor shall be kept dry and free of standing water. |