Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameINSPIRE SOUTHPARK
Address345 SHARON TOWNSHIP LANE
 
City/State/ZIP
CHARLOTTE NC 28211
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 3/29/2023
Final Score @ Grade
34
General CommentsInspection completed with Jonatan Hernandez present. Permit suspended for all items listed below. Once corrected, contact Eli Freese at 704.621.2298 to verify and reopen pool/spa. 1. Chlorine at 0ppm. 2. The pH at 6.8. 3. Emergency phone unable to receive incoming calls. 4. One drain cover completely detached from suction outlet. NOTE: Drain covers are expiring in May, 2023. Replace prior to April 31, 2023 and submit a new pool drain suction compliance (PDSC) form to the health department for verification and approval to receive your operations permit.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Observed chlorine at 0ppm. Permit suspended.
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH below 6.8. Permit suspended.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2537(7) Drain covers shall be in good condition and securely attached. Observed 1 drain cover completely detached from suction outlet. Permit suspended. Pump shut down.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed gate nearest the spa not self-closing. Correct or an intent to suspend will be issued.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Observed emergency phone unable to receive calls that are dialed into it. Permit suspended.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed non-operational flow meter.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Observed water on pump room floor due to faulty gasket at spa pump.