Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameWINDSOR RUN - SPA
Address2030 WINDSOR RUN LANE
 
City/State/ZIP
MATTHEWS NC 28105
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 10/21/2026
Final Score @ Grade
18
General CommentsEmergency phone will be checked for callback in 7 days, main drain screw will be checked for replacement, Wednesday October 28, permit will be suspended immediately at this time if not correct. Indicate correct callback number on signage (only one number). Contact Marie Daley at 704-507-6806 when in compliance. 30 Day Intent to Suspend (ITS) for fittings replaced. Permit restriction pump must remain set so that flow does not exceed 98 GPM due to skimmer restriction. Flow meter must remain operable. Inspection with Chris Gundacker and Jessica Sprague

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Drain cover missing one screw out of 16. Drain appears secure, manufacturer specifications include 16 screws. Replace to meet specs. Allowing 7 days since drain cover is secure. .2537(7) Drain covers shall be in good condition and securely attached. *permit item
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Observed 6 missing fittings. Replace. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. *permit item
22 6 Premises: emergency telephone provided No No No Emergency phone not calling back to phone. Does dial out in case of emergency. Allowing 7 days to correct due to ability to call out in case of emergency. .2530 Emergency phone shall either audibly ring or answer automatically when phone number for phone is dialed. .2530(f) Emergency notification systems (monitoring services) must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer the phone number and address for the phone to 911. *permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Water on floor due to leak at spa jet pump. Items within 3 ft of pump. .2533(d) Pump room floor shall be kept dry and free of standing water. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.