2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Chlorine at 0.2 ppm at time of inspection.
.2535(4) Maintain chlorine at least 1.0 ppm.
*immediate suspension item |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Ring buoy dry rotted and mildewed such that it is in poor repair and no longer meets USCG standards. Rope no longer attached to buoy.
*immediate suspension item |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2537(b) All gates and doors shall be self-closing, self-latching. Two gates standing open upon arrival for inspection do not self-close and latch. *permit item
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Fence with damage to vertical picket resulting in greater than 4” opening. Pool built 2018.
*permit item |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency phone shall remain operable. Kings III emergency notification system not operational. Unable to connect. This system appears to malfunction after rain events. EHS strongly recommends relocating this system to alternate location that is sheltered from water intrusion.
*immediate suspension item |