NameAVANA MATTHEWS
Address2808 CROSS POINT CIR
 
City/State/ZIP
MATTHEWS NC 28105
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/16/2023
Final Score @ Grade
30
General CommentsInspection completed with Arthur Dube present. Immediate suspension of pool permit issued for the following: 1. The pH at 6.8. Maintain between 7.2 and 7.8. 2. Emergency phone cannot receive incoming calls. Contact Eli Freese at 704.621.2298 once these above items are corrected to verify and reopen pool. The items listed below are intent to suspend items if not corrected once the immediate suspension is lifted: 1. 3 out of 5 weirs missing. 2. Chlorine chemical feeder remaining operable when pump has no power. General comment: Observed 2 missing backsplash tiles at top of pool wall.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 6.8. Permit suspended.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed debris in pool. Maintain clean.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed 3 weirs missing out of 5 total.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Observed phone working properly when making outgoing calls but not capable of receiving incoming calls. Permit suspended. Ensure the emergency phone is capable of receiving incoming calls.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No .2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. Observed automatic chlorine feeder remains on and operable when pump has no power.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed flow meter non-operational.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Observed no toilet paper in restroom nearest pool.