Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMURRAY, THE
Address8010 WOODSEDGE DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/16/2025
Final Score @ Grade
12
General CommentsInspection conducted with maintenance staff Eligio Queliz. No diving marker cracked. Maintain in good condition. Throw rope fraying, outer rope on ring buoy starting to fray. Recommend replacing with new US Coast Guard approved ring buoy with attached 41 foot throw rope at least 1/4 inches in diameter.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy outer rope all on one side. Throw rope fraying and heavily knotted. .2530(a) Provide USCG approved ring buoy with attached 41 foot throw rope. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence with footholds at grill area. .2528(b) Horizontals shall not be located less than 45" in height. Pre-2010 fence. Most fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Lights burned out in the pump room. .2533(b) Provide sufficient lighting in pump room. Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.