15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy outer rope all on one side. Throw rope fraying and heavily knotted. .2530(a) Provide USCG approved ring buoy with attached 41 foot throw rope. - Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence with footholds at grill area. .2528(b) Horizontals shall not be located less than 45" in height.
Pre-2010 fence. Most fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Lights burned out in the pump room. .2533(b) Provide sufficient lighting in pump room.
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |