Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMURRAY, THE
Address8010 WOODSEDGE DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/27/2023
Final Score @ Grade
22
General CommentsInspection conducted with CPO Henry Ramirez. Recommend recalibrating chemical controller. Tested Cl > 10ppm free chlorine, controller read 507 ORP, pH tested at 7.0, reading 7.4. Intent to suspend issued 5)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Operator unable to locate log book. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item. No log book on site. .2535(11) The pool operator must maintain records for at least six months. - Intent to suspend item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope 32.5 ft long, tangled around ring buoy. .2530(a) Provide USCG approved ring buoy with attached 41 foot throw rope. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence with footholds at grill area. .2528(b) Horizontals shall not be located less than 45" in height. Pre-2010 fence. Some fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Gate latch broken. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. Fan turned off in the chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. - Corrected. One light burned out, other light mostly out, periodically flickers. .2533(b) Provide sufficient lighting in pump room.