16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence. Some fence sections < 48" high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Section of fence not anchored to office wall. .2528 Ensure fencing is securely installed.
Windows from the office onto the pool deck capable of opening > 4". .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan not working in the pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
New plumbing in the pump room not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
One of the restrooms closed for repairs. .2526(a) Provide restrooms in good condition. |