General CommentsInspection conducted with CPO Gerardo Ozoria. Flow meter not working, ~10 psi on filter pressure gauges. Operator unable to backwash to reduce water level. Ensure pump and equipment are operating properly. Immediate suspension issued 2) 15) Contact Will Harrison (704) 507-6824 for re-inspection once issue have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No 0.1ppm free chlorine. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No total alkalinity, cyanuric acid, or main drains checks. No weekend checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Leaves and debris on pool floor. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir missing, three weirs damaged. .2518(k) Provide functional weirs. - Intent to suspend item. Water level above the skimmers. .2518(k) Water level shall be maintained to assure skimmers are operable. - Intent to suspend item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy damaged. .2530(a) Provide US Coast Guard approved ring buoy with 50 foot throw rope at least 1/4 inch in diameter. - Immediate suspension item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence less than 48” throughout. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pre-2010 fence with gaps > 4" under the fence in places. .2528(b) Maintain fencing with gaps no greater than 4” under fence. Observed 4” gap under main gate. .2528(a) Maintain 2" or less under pool gate. Maintain gate at least 48” high. - Intent to suspend item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pool overfilled, decking by back gate flooded with standing water. .2522(f) Deck shall be sloped to drain. - Intent to suspend item.
18 4 Premises: lifeguards present or warning signs posted No No No New safety signage in less than 4” lettering. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. - Intent to suspend item. New safety signage in less than 1” lettering. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Intent to suspend item. New safety signage in less than 1” lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item. Spare pump basket broken. .2518(e) Provide a spare basket for pump. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Light burned out in pump room. .2533(b) Provide sufficient lighting in pump room. Fan not present in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Desk and other items stored by equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.