Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCASCADES AT NORTHLAKE
Address8700 LONG CREEK CLUB DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/4/2024
Final Score @ Grade
20
General CommentsInspection conducted with CPO David Johnson. Back gate had magnetic latch installed. Latch < 45” high and extended out > 1” and created a foothold. Latch release was also located directly on the fence and was easy for children to reach. If reinstalled. Ensure magnetic latch does not create a foothold, is not accessible to children (no openings > 1/2” within 18” of release button), and operates on a battery backup. Permit issued No night swimming Paper permit will be on our website in 3-5 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 7.9. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.7.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence as short as 45” high in places due to mulch. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pre-2010 fence with gaps > 4" under the fence in places. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Gate by pump room broken. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. Will need to fix broken welds on gate. - Corrected. One gate with new magnetic latch, creating a foothold < 45” high. .2528(b) Horizontals and footholds shall not be located less than 45" in height. - Corrected. Magnetic latch removed.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some chairs too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected. Spare pump basket not observed. .2518(e) Provide a spare basket for pump. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Light burned out in pump room. .2533(b) Provide sufficient lighting in pump room.