Water quality: pool water pH |
No |
No
|
No |
pH 7.9. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.7. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence as short as 45” high in places due to mulch. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Pre-2010 fence with gaps > 4" under the fence in places. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
Gate by pump room broken. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. Will need to fix broken welds on gate. - Corrected.
One gate with new magnetic latch, creating a foothold < 45” high. .2528(b) Horizontals and footholds shall not be located less than 45" in height. - Corrected. Magnetic latch removed. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some chairs too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected.
Spare pump basket not observed. .2518(e) Provide a spare basket for pump. - Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Light burned out in pump room. .2533(b) Provide sufficient lighting in pump room. |