5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No recent total alkalinity checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide recordings for cyanuric acid and total alkalinity weekly. - Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence as short as 45” high in places due to mulch. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Pre-2010 fence with gaps > 4" under the fence in places. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
Loose picket in gate by mailboxes with gap > 4” through the gate. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". - Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Much of chemical storage room full of general, non-chemical items, and chemicals jumbled on top of each other. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
Fan in the pump room gone. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |