Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCASCADES AT NORTHLAKE
Address8700 LONG CREEK CLUB DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/29/2022
Final Score @ Grade
30
General CommentsInspection conducted with Kim Lucas. Immediate suspension issued 3) 22) Contact Will Harrison (704-507-6824) when issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH < 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope not attached to ring buoy. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48" high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pre-2010 fence with gaps > 4" under the fence in places. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
22 6 Premises: emergency telephone provided No No No Emergency phone not readily visible due to large pillars. Temporary signage in place on last inspection has been removed. .2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. - Corrected. Unable to hear Kings III operator. .2530(f) Emergency phone shall remain operable. - Immediate suspension item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Dry chemicals stored on the ground in the pump room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No New piping installed in pump room not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.