NameCASCADES AT NORTHLAKE
Address8700 LONG CREEK CLUB DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/2/2021
Final Score @ Grade
38
General CommentsInspection conducted with Kim Lucas. Due to COVID-19 precautions, inspection was not signed by the operator. Pre-permit items noted on previous inspection have been corrected. New issues observed on today's inspection. Appears that pool has been open and operating without a permit. Pool closed signs were not observed. Keep pool closed until after receiving a passing inspection and a permit to operate from Mecklenburg County Public Health. Pre-permit inspection did not pass. A $100 reinspection fee will need to be paid prior to scheduling reinspection. This can be done by calling our main office, 980-314-1620 and paying with a credit card. Permit denied 1) 3) 5) Contact Will Harrison (704) 507-6824 to schedule reinspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
1 6 Water quality: water clear enough to clearly see bottom of pool and pool drain No No No Pool became too cloudy to see main drains and pool bottom after operator added soda ash to correct pH. .2535(2) Main drains must be clearly visible from the pool deck. - Started to clear, clumps of soda ash stirred up by Dolphin and got worse again. - Pre-permit item.
3 6 Water quality: pool water pH No No No pH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Operator unable to adjust, pH locked due to high cyanuric acid level. - Pre-permit item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Cyanuric acid well above 100ppm. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. - Pre-permit item. Out of cyanuric acid reagent. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Pre-permit item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Most skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Body hook on a collapsible pole. .2530(a) 12 foot pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48" high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pre-2010 fence with gaps > 4" under the fence in places. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Table too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Fan missing in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No New piping installed in pump room not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.