Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCASCADES AT NORTHLAKE
Address8700 LONG CREEK CLUB DR
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/18/2021
Final Score @ Grade
24
General CommentsInspection conducted with Quintin Rankin. Due to COVID-19 precautions, inspection was not signed by the operator. Chairs on the sunshelf with metal bars that are corroded, some snapped in half. Ensure furniture in the pool is designed for commercial pool use in the pool. - Damaged chairs removed. Pre-permit inspection did not pass. A $100 reinspection fee will need to be paid prior to scheduling reinspection. This can be done by calling our main office, 980-314-1620 and paying with a credit card. Permit denied 15) 22) 24) Contact Will Harrison (704) 507-6824 to schedule reinspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy coming apart. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope. - Pre-permit item. Body hook on a collapsible pole. .2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible at least 12 feet in length. - Pre-permit item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48" high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pre-2010 fence with gaps > 4" under the fence in places. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
22 6 Premises: emergency telephone provided No No No Emergency phone does not accept incoming calls. .2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system and shall be capable of accepting incoming calls - Pre-permit item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Vacuum cap not securely closed. Ensure cap is closed such that it is only openable with a tool after done vacuuming. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Corrected. Flow meter stuck. .2518(g) Keep flow meter operational. - Pre-permit item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Much of chemical storage room full of general, non-chemical items. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Fan in the pump room gone. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No New piping installed in pump room not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.