15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy coming apart. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope. - Pre-permit item.
Body hook on a collapsible pole. .2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible at least 12 feet in length. - Pre-permit item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence < 48" high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Pre-2010 fence with gaps > 4" under the fence in places. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone does not accept incoming calls. .2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system and shall be capable of accepting incoming calls - Pre-permit item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Vacuum cap not securely closed. Ensure cap is closed such that it is only openable with a tool after done vacuuming. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Corrected.
Flow meter stuck. .2518(g) Keep flow meter operational. - Pre-permit item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Much of chemical storage room full of general, non-chemical items. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
Chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Fan in the pump room gone. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
New piping installed in pump room not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels. |