Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCASCADES AT NORTHLAKE
Address9840 LONGVIEW CLUB LN
 
City/State/ZIP
CHARLOTTE NC 28216
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/30/2018
Final Score @ Grade
28
General Comments23 - General Comment - Pool is equipped with two salt systems. Swimming pool is not approved for primary chlorination through salt system. Must go through approved chlorinator. Salt system is only capable of producing 2.9 lbs per 24 hours for both. Required 3 lbs per 10,000 gallons per 24 hours. Note: Glass bulb in light above emergency phone. No glass on pool deck. Intent to Suspend issued for record keeping, skimmer weir, gate issues, storage of chemicals, deck damage.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records not maintained. CPO required to maintain chlorine, pH, and main drain checks in log book daily. Record cyanuric acid and alkalinity weekly. Intent to Suspend issued. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir missing from skimmer and baskets with some debris. Replace weir and keep skimmers clean. Intent to Suspend issued. .2518(k) Replace missing weirs. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder missing end cap. Replace missing end cap. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy rope crumbling due to weathering. Provide a 45 ft rope. Operator took rope from sister property whose permit is already suspended. Corrected during the inspection. An immediate suspension has been issued for rope at other property.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One gate with latching mechanism broken. Intent to Suspend issued. .2537(b) All gates and doors shall be self-closing, self-latching. One gate with damage to picket, >4" between. Intent to Suspend issued. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". All gates with magna-latches and protrusion of latch at 36" in height measured from ground. Desks located next to fence area as storage. Eliminate footholds. Intent to Suspend issued. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some deck damage near pump room where deck has chipped out. Intent to Suspend issued. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. One lounge chair at 4 1/2 ft from pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Liquid chemicals stored over dry chemicals in chemical storage room. Intent to Suspend issued. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Light burnt out in pump room. .2533(b) Provide sufficient lighting in pump room.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No One restroom without toilet paper in women's. Men's not viewed at time of inspection. .2626(l) Provide toilet paper and dispensers in restrooms. Mirrors could not be verified as shatterproof at time of inspection. .2626(k) Provide shatterproof mirrors.