NameFOUNTAINS MATTHEWS
Address10625 PARRISH ST
 
City/State/ZIP
MATTHEWS NC 28105
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/13/2020
Final Score @ Grade
4
General CommentsPOOL HAS AQUASTAR FOUR 6HP EQ LINE COVERS AND ONE AQUASTAR A10RCFR EQ LINE COVER. AQUASTAR HAS CHANGED THE CERTIFIED FLOW RATE FOR THE 6HP COVERS TO 92GPM. THE FLOW RATE FOR THE A10RCFR HAS NOT BEEN CHANGED THAT I AM AWARE OF. THESE COVERS EXPIRE JULY2021. WHEN THE CURRENT COVERS EXPIRE, NEW COVERS MUST BE RATED FOR THE REQUIRED FLOW RATE OF THE CIRCULATION SYSTEM. THE MAIN DRAINS WILL ALSO EXPIRE JULY 2021 AND WILL REQUIRE REPLACEMENT. WHEN THESE ITEMS ARE REPLACED, PDSC PAPERWORK WILL HAVE TO BE SUBMITTED TO THE HEALTH DEPARTMENT FOR APPROVAL. IT WAS OBSERVED THAT THE SAND FILTER HAS BEEN CHANGED OUT LIKE-FOR-LIKE (TR-140C MODEL NUMBER) AND THAT THE MOTOR FOR THE WFE-12 3HP PUMP HAS BEEN CHANGED. THE NEW MOTOR HAS SUFFICIENT HORSE POWER AND SEEM PROPER FOR THIS PUMP. THE PUMP WAS NOT CHANGED. AN ELECTRICAL PERMIT AND INSPECTION MUST BE PROVIDED FOR THIS CHANGE IN MOTOR. THE HEALTH DEPARTMENT COULD NOT FIND ANY RECORD THAT THIS WAS DONE. IT MUST BE DONE OR THE POOL COULD BE CLOSED UNTIL THE ELECTRICAL PERMIT/INSPECTION IS RESOLVED. IT WAS OBSERVED THAT THE CALL BOX WAS FUNCTIONAL, HAD THE RIGHT ADDRESS, AND THAT THE ADDRESS AND PHONE NUMBER WERE PROPERLY LISTED WITH LOCAL 911 SERVICES. THE BOX WAS NOT, HOWEVER, ABLE TO BE CALLED BACK BY THE LISTED PHONE NUMBER. THE BOX MUST BE ABLE TO BE CALLED BACK AND PROVIDE VOICE COMMUNICATION THROUGH THE BOX. THIS MUST BE CORRECTED. C. ELMORE WILL PERFORM A FOLLOW-UP VISIT TO EVALUATE THESE ITEMS ON OR ABOUT 8/28/2020. POOL IS NOT APPROVED FOR NIGHT SWIMMING. IF NIGHT SWIMMING IS DESIRED, A NIGHT SWIMMING EVALUATION MUST BE PERFORMED. CONTACT C. ELMORE AT 704-507-6814 FOR THIS EVALUATION IF NIGHT SWIMMING IS DESIRED. "issuance of a permit by this department does not negate closure required by Executive Order No. 120, 138, 141, 147, or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order." NO SIGNATURE WAS OBTAINED DUE TO COVID-19 SOCIAL DISTANCING.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed gaps in the records for August. Chlorine, pH, and main drains/EQ lines must be checked and recorded every day the pool is open. Total Alkalinity and Cyanuric Acid (if Cyanuric Acid/Stabilizer is in use in the pool) must be checked and recorded at least once a week. No permit action taken, but C. Elmore will evaluate record keeping on or about 8/28/2020 for compliance.