Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameFOUNTAINS MATTHEWS
Address10625 PARRISH ST
 
City/State/ZIP
MATTHEWS NC 28105
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/18/2019
Final Score @ Grade
4
General CommentsPool has 4 Aquastar 6HP equalizer covers (EQ covers). These have had the certified flow rate lowered by the manufacturer to 92GPM. The EQ covers for this pool expire July 2021. When they are replaced, ensure that the covers used in replacement are suitable for the flow rate of the pump system.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed gaps in the records kept. Ensure that pH, Chlorine, Main Drains/EQ covers, and Temperature (if pool is heated) are checked and recorded every day the pool is open to swimming. This includes weekends and holidays. A CPO does not have to be the one who performs the checks and recording, a CPO does have to observe the pool at least 1 time a day. Total Alkalinity and Cyanuric Acid (if used) must be checked and recorded at least one time a week. Cyanuric acid cannot exceed 100ppm. No permit action taken, most records were properly kept.